Maximum admissible power (potencia máxima admisible)

The highest power an installation can carry, set by the size of its individual riser cable and the rating of its main switch. It is stated on the boletín and marks how far you can raise your contracted power without work or a new certificate.

What potencia máxima admisible is

Potencia máxima admisible (maximum admissible power) is the ceiling of your installation: the power its cables and protective devices can carry without overheating. It depends mainly on the size of the individual riser cable (derivación individual), the line from the meter to your consumer unit, and on the rating of the main switch (IGA).

Where to find it

It is stated on the boletín, the installation certificate issued by the installer. If you do not have it to hand, the rating of the main switch gives a clue on a 230 V single-phase supply:

  • 25 A: about 5,750 W.
  • 32 A: about 7,360 W.
  • 40 A: about 9,200 W.

This is only a reference: what counts is what the riser cable can carry, and only an electrician can check that.

What it is for

If you want more contracted power and the new figure does not exceed the maximum admissible power on a boletín under 20 years old, you can normally just ask your supplier (comercializadora). If it does, or the boletín is older, the distributor will ask for a new certificate.

If it falls short

Raising it means upgrading the installation: a new main switch and sometimes a new riser cable or consumer unit. A new boletín is then issued and registered with the regional industry office. First, check whether you really need more power or whether spreading your usage or a load balancer for the EV charger would do.

See increase contracted power in Seville, Spain.